getBlockInfo_HwInterrupt_multilink_mpc5500(linkPjtGenInfo, schedPjtGenInfo)
function [linkPjtGenInfo, schedPjtGenInfo] = getBlockInfo_HwInterrupt_multilink_mpc5500(linkPjtGenInfo, schedPjtGenInfo)
%GETBLOCKINFO_HWINTERRUPT_MULTILINK_MPC5500 Get information about a 'Hardware Interrupt' block.

%   $Revision: 1.1.6.1 $ $Date: 2012/04/02 21:40:09 $
%   Copyright 2007-2010 The MathWorks, Inc.

%----------------------------------------------------------
% Look for HW Interrupt blocks in the model
%----------------------------------------------------------
hwInterruptBlocks = linkfoundation.util.FindSystem(linkPjtGenInfo.modelName,'MPC5500 Interrupt Block');

%----------------------------------------------------------
% Check for error conditions
%----------------------------------------------------------
numHwIntBlks = length(hwInterruptBlocks);
if numHwIntBlks==0
    % No HW Interrupt block present in the model
    return;
elseif numHwIntBlks> 1
    % Only 1 HW Interrupt is allowed in the model
    linkPjtGenInfo.error = 1;
    linkPjtGenInfo.errormsg = 'Only one Hardware Interrupt block is allowed in the model';
    return
end

%----------------------------------------------------------
% Update 'schedPjtGenInfo' if a HW Interrupt block is present
%----------------------------------------------------------
% linkPjtGenInfo.numInterrupts  - Number of interrupts in the model
% linkPjtGenInfo.interrupts     - List of interrupt numbers
% linkPjtGenInfo.priority       - List of interrupt priorities
% linkPjtGenInfo.isrpreempt     - List of interrupt preempts
%
% linkPjtGenInfo.softwareVectMode
% linkPjtGenInfo.baseRatePriority
% linkPjtGenInfo.asmFileName
% linkPjtGenInfo.offset
%----------------------------------------------------------

if ~isempty(hwInterruptBlocks)

    % Get information specified by user
    irqnum = get_param (hwInterruptBlocks, 'irqnumbers');
    interruptNumbers = eval(cell2mat(irqnum));
    
    priort = get_param(hwInterruptBlocks,'syspriorities');
    sysPriority = eval(cell2mat(priort)); 
    
    preemp = get_param(hwInterruptBlocks,'irqpreempts');
    irqPreempt = eval(cell2mat(preemp));
    
    softmode = get_param(hwInterruptBlocks,'softwaremode');
    linkPjtGenInfo.softwareVectMode = strcmpi(softmode,'on');
    
    linkPjtGenInfo.baseRatePriority = getBaseTaskPriority(linkPjtGenInfo.modelName);

    linkPjtGenInfo.asmFileName = '';
    if ~(linkPjtGenInfo.softwareVectMode)
        linkPjtGenInfo.asmFileName = 'multilink_mpc5500_hw_vect.asm';
    end
    
    for i=1:length(interruptNumbers)      
        % Increment number of interrupts by 1
        linkPjtGenInfo.numInterrupts = linkPjtGenInfo.numInterrupts + 1;

        % Assign the interrupt number - given by user
        linkPjtGenInfo.interrupts{linkPjtGenInfo.numInterrupts} = interruptNumbers(i);

        % Assign the interrupt priority - given by user
        linkPjtGenInfo.priority{linkPjtGenInfo.numInterrupts}   = int32(sysPriority(i));
        
        % Assign the interrupt preempt - given by user
        if length(irqPreempt)>1
            linkPjtGenInfo.isrpreempt{linkPjtGenInfo.numInterrupts} = irqPreempt(i);
        else
            linkPjtGenInfo.isrpreempt{linkPjtGenInfo.numInterrupts} = irqPreempt(1);
        end     
        
        if (linkPjtGenInfo.softwareVectMode)
            linkPjtGenInfo.offset{linkPjtGenInfo.numInterrupts} = '';
        else
            linkPjtGenInfo.offset{linkPjtGenInfo.numInterrupts} = dec2hex(hex2dec('40000000')+interruptNumbers(i)*16);
        end
        
    end
    
end

%% --------------------------------------------------------------------------------
function baseTaskPriority = getBaseTaskPriority(modelName)
baseTaskPriority = 7;  %default
cs = getActiveConfigSet(modelName);
solverType = get_param(cs, 'SolverType');
if ( ~strcmp(solverType, 'Fixed-step')  )
    return %we shouldn't be here in the first place...
end
sampleTimeConst = get_param(cs, 'SampleTimeConstraint');
if ( strcmp(sampleTimeConst, 'Specified') )
    % Priorities are specified by the user and we always ensure that
    % these lie in between 1-15 (TSK)
    sampleTimeProp = get_param(cs,'SampleTimeProperty');
    baseTaskPriority = sampleTimeProp.Priority;
end

%[EOF] getBlockInfo_HwInterrupt_multilink_MPC5500.m