getBlockInfo_multilink_getSimPriority(modelName, moduleName, sysPriority)
function simPriority = getBlockInfo_multilink_getSimPriority(modelName, moduleName, sysPriority)
% simPriority = getBlockInfo_multilink_getSimPriority(moduleStr, moduleName, biosPriority)


% If the baseRate is specified then set the simPriority to sysPriority
% else map sys 7 to sim 40 (default) 
% and calculate HWI relative to that scale.
% moduleName = 'IDL' or 'HWI'
% 

% Copyright 2005-2011 The MathWorks, Inc.

% Retrieve sim. config parameters
cs = getActiveConfigSet(modelName);
solverType = get_param(cs, 'SolverType');
if ( ~strcmp(solverType, 'Fixed-step')  )
    simPriority = sysPriority;
    return
end

sampleTimeConst = get_param(cs, 'SampleTimeConstraint');
BaseRateTskPriority = 7;
specified = strcmp(sampleTimeConst, 'Specified');
if ( specified )
    % Priorities are specified by the user and we always ensure that
    % these lie in between 1-15 (TSK)
    sampleTimeProp = get_param(cs,'SampleTimeProperty');
    BaseRateTskPriority = sampleTimeProp.Priority;
end

switch moduleName
    case 'IDL'
        % 15
        maxSys = max(sysPriority);
        simPriority = sysPriority - (maxSys +1);
                
    case 'HWI'
        % HWI priority in this case ranges from 0 to 15
        if ( any(sysPriority < 0) || any(sysPriority > 15) )
            error(message('GHSMULTIEXT:util:InvalidInterruptRange'));
        end
        if (specified)
            simPriority = sysPriority;
        else
            simPriority = sysPriority + (40 - BaseRateTskPriority);
        end
    otherwise
        error(message('GHSMULTIEXT:util:InvalidModuleName'));
end
        
    