File Exchange

image thumbnail

BASIC SINGLE PHASE FULL WAVE THYRISTOR BASED AC VOLTAGE CONTROLLER WITH RESISTIVE LOAD

version 1.0 (9.36 KB) by

single phase fullwave thyristor based AC voltage controller.

4 Downloads

Updated

View License

AC voltage controller is used to convert fixed AC voltage to a variable AC voltage
without changing the given frequency.
in this model the load is resistive (150 ohms) and given firing angle is 30 degrees.
this model is helpful in understanding the nature of output waveform for a given firing angle.
the model which i have uploaded is the basic one which will be helpful for bachelor students and new simulink, simpowersystems users.

Comments and Ratings (4)

good

za ra

za ra (view profile)

here is your answer.
double click on pulse generator block.
then first set the period with respect to time base ie; 0.02 sec( because in india frequency is 50 cycles/sec. therefore 1cycle or period=360 degrees=0.02 sec)
then enter phase delay(ie;firing angle) as
(x*0.02)/360 where 'x' stands for your desired firing angle in degrees.
if firing is required for negative cycle, then
phase delay= ((x+180)*0.02)/360.
hope it will help.

priya

priya (view profile)

Hi,i want to know how to set the firing angle in case of pulse generators..

MATLAB Release