Rank: 228 based on 397 downloads (last 30 days) and 7 files submitted
photo

ankush laddha

E-mail
Company/University
IIT Bombay

Personal Profile:
Professional Interests:
load emulation, inverters, statcom

 

Watch this Author's files

 

Files Posted by ankush View all
Updated   File Tags Downloads
(last 30 days)
Comments Rating
26 Sep 2012 Screenshot Three phase Stacom, Active front end rectifier and DC-link stabilizer two level three phase active font and statcom Author: ankush laddha statcom, active front end rect..., dclink stabilizer, matlab simulink, power electronics 78 1
  • 4.25
4.2 | 4 ratings
22 Sep 2011 Screenshot three phase three level current control using space vector current control is implement using hexagonal hysteresis current error band Author: ankush laddha current control, three level inverter, simulation, simulink 46 1
  • 4.0
4.0 | 2 ratings
20 Sep 2011 Screenshot STATCOM using hysteresis current control technique based on hysteresis current control Author : Ankush Laddha (IIT-BOMBAY) rate this file Author: ankush laddha statcom, hysteresis current co..., inverter, simulink, simulation 54 0
20 Sep 2011 Screenshot STATCOM using constant MI variable DC bus voltage based on delta control & has constant switching freq Author : Ankush Laddha (IIT-BOMBAY) Author: ankush laddha statcom, inverter, simulink, simulationpower syste..., reactive power 47 0
  • 4.0
4.0 | 1 rating
20 Sep 2011 Screenshot three phase phase locked loop ( PLL ) three phase PLL author Ankush Laddha (IIT-Bombay) please rate this file & also send me comments Author: ankush laddha pll, simulation, simulink, control design, inverter 47 1
  • 4.0
4.0 | 2 ratings
Comments and Ratings on ankush's Files View all
Updated File Comment by Comments Rating
06 Feb 2014 two (2) level space vector based pulse width modulation of 3 phase inverter a fast 2 level space vector modulation author:ankush laddha (IIT - Bombay) please rate this file Author: ankush laddha Sous, Mar

How do you specify Vdc input? You have a 400V voltage source in the DC link but in the SVM controller it is a constant 2.
Can you explain? Thanks.

08 Dec 2013 two (2) level space vector based pulse width modulation of 3 phase inverter a fast 2 level space vector modulation author:ankush laddha (IIT - Bombay) please rate this file Author: ankush laddha Ray, Soumya

Output Voltage is coming properly.

26 Aug 2013 Three phase Stacom, Active front end rectifier and DC-link stabilizer two level three phase active font and statcom Author: ankush laddha Poorghasemi Khiyavi, Asgar

hi
tanks for file

07 Jun 2013 Three phase Stacom, Active front end rectifier and DC-link stabilizer two level three phase active font and statcom Author: ankush laddha zwbscg

31 May 2013 STATCOM using constant MI variable DC bus voltage based on delta control & has constant switching freq Author : Ankush Laddha (IIT-BOMBAY) Author: ankush laddha OMER, PRABHU

Contact us