Third-Party Products & Services
ACD
Automatic controller design and automatic robust controller design
Highlights
- Desired time-domain closed loop behavior is considered
- Computes parameters for the Anti-Reset-Windup compensator structure
- Stability of closed loop is guaranteed
- Considers additional plant models for robust controller design
- Optional optimization for disturbance rejection or reference behavior
Description
ACD automatically calculates the parameters for well-known compensator types (P, PI, PD, PID) or alternatively for a generalized controller of user-defined order. The controller parameters are optimized with respect to a plant model and additional user options. The desired time-domain closed loop behavior is considered and may be defined graphically by a goal curve for the desired closed loop step response. Additionally, ACD provides the parameters for an ti-Reset-Windup compensator structure to avoid undesired windup effects of compensators with integral parts. For robust controller design, up to three plant model transfer functions can be considered additionally for calculating optimized robust controller parameters.
MathWorks products required
Support
- On-site assistance
- Telephone
- Training
Platforms
- Windows
Industries and Tasks
- Aerospace and Defense
- Automotive
- Chemical and Petroleum
- Control Design
- Electronics
- Industrial Automation And Machinery
- Vibration Analysis and Control
- Consulting
ExpertControl GmbH
Strittholzstrasse 31
Herrsching, 82211
GERMANY
Tel: +49-7000-397-37-87
Fax: +49-8152-9099214
E-mail
Web:
www.expertcontrol.com