Flow restriction of fixed area modeled per ISO 6358
Simscape / Fluids / Gas / Valves & Orifices
The Orifice ISO 6358 (G) block models the pressure loss incurred in a gas network due to a purely resistive element of fixed size—such as a flow restriction, an orifice, or a valve—using the methods outlined in the ISO 6358 standard. These methods are widely used in industry in the measurement and reporting of gas flow characteristics. The availability of data on the coefficients of the ISO formulas makes the ISO parameterizations useful when component geometries are unavailable or cumbersome to specify.
The default orifice parameterization is based on the most recommended of the ISO 6358 methods: one based on the sonic conductance of the resistive element at steady state. The sonic conductance measures the ease with which a gas can flow when choked, a condition in which the flow velocity is at its theoretical maximum (the local speed of sound). Choking occurs when the ratio between downstream and upstream pressures reaches a critical value known as the critical pressure ratio
The remaining parameterizations are formulated in terms of alternative measures of flow capacity: the flow coefficient (in either of its forms, Cv or Kv) or the size of the flow restriction. The flow coefficient measures the ease with which a gas can flow when driven by a certain pressure differential. The definition of Cv differs from that of Kv in the standard pressure and temperature established in its measurement and in the physical units used in its expression:
Cv is
measured at a generally accepted temperature of 60°F
and pressure drop of 1 PSI; it is expressed in
imperial units of US gpm. This is the flow
coefficient used in the model when the Orifice
parameterization block parameter is set to
Cv coefficient (USCS).
Kv is
measured at a generally accepted temperature of 15°C
and pressure drop of 1 bar; it is expressed in metric
units of m^3/h. This is the flow coefficient used in
the model when the Orifice parameterization block
parameter is set to Kv coefficient
(SI).
The volume of fluid inside the resistive element, and therefore the mass of the same, is assumed to be very small and it is, for modeling purposes, ignored. As a result, no amount of fluid can accumulate there. By the principle of conservation of mass, the mass flow rate into the valve through one port must therefore equal that out of the valve through the other port:
where is defined as the mass flow rate into the valve through the port indicated by the subscript (A or B).
The causes of the pressure losses incurred in the passages of the resistive element are ignored in the block. Whatever their natures—sudden area changes, flow passage contortions—only their cumulative effect is considered during simulation. It is this cumulative effect that the sonic conductance in the default orifice parameterization captures in a model. If a different parameterization is selected, the coefficients on which it is based are converted into the parameters of the default parameterization; the mass flow rate calculation is then carried out as described in Sonic Conductance Parameterization.
In a choked flow, the mass flow rate through the resistive element is calculated as:
where:
C is the sonic conductance inside the resistive element.
ρ is the gas density, here at standard
conditions (subscript 0, 1.185
kg/m^3).
p is the absolute gas pressure, here
corresponding to the inlet (in).
T is the gas temperature at the inlet
(subscript in) or at standard conditions
(subscript 0, 293.15
K).
In a subsonic and turbulent flow, the mass flow rate calculation becomes:
where:
pr is the ratio between downstream pressure (pout) and upstream pressure (pin) (each measured against absolute zero):
bcr is the critical pressure ratio at which the gas flow first begins to choke.
m is the subsonic index, an empirical coefficient used to more accurately characterize the behavior of subsonic flows.
In a subsonic and laminar flow, the mass flow rate calculation changes to:
where blam is the critical pressure ratio at which the flow transitions between laminar and turbulent regimes. Combining the calculations for the three flow regimes into a piecewise function gives across all pressure ratios:
If the orifice parameterization is set to Cv coefficient
(USCS), the parameters of the mass flow rate calculation are
set as follows:
Sonic conductance: C = 4E-8 * Cv m^3/(s*Pa)
Critical pressure ratio: bcr = 0.3
Subsonic index: m = 0.5
If the Kv coefficient (SI) parameterization is
used:
Sonic conductance: C = 4.78E-8 * Kv m^3/(s*Pa)
Critical pressure ratio: bcr = 0.3
Subsonic index: m = 0.5
For the Restriction area parameterization:
Sonic conductance: C = 0.128 * 4
SR/π
L/(s*bar), where S is the flow area in the
resistive element (subscript R).
Critical pressure ratio: bcr = 0.41 + 0.272 (SR/SP)^0.25
Subsonic index: m =
0.5
The resistive element is modeled as an adiabatic component. No heat exchange can occur between the fluid and the wall that surrounds it. No work is done on or by the fluid as it traverses from inlet to outlet. With these assumptions, energy can flow by advection only, through ports A and B. By the principle of conservation of energy, the sum of the port energy flows must then always equal zero:
where ϕ is defined as the energy flow rate into the valve through one of the ports (A or B).
[1] P. Beater, Pneumatic Drives, Springer-Verlag Berlin Heidelberg, 2007.