Interior PMSM

Three-phase interior permanent magnet synchronous motor with sinusoidal back electromotive force

  • Library:
  • Powertrain Blockset / Propulsion / Electric Motors

Description

The Interior PMSM block implements a three-phase interior permanent magnet synchronous motor (PMSM) with sinusoidal back electromotive force. The block uses the three-phase input voltages to regulate the individual phase currents, allowing control of the motor torque or speed.

By default, the block sets the Simulation type parameter to Continuous to use a continuous sample time during simulation. If you want to generate code for fixed-step double- and single-precision targets, considering setting the parameter to Discrete. Then specify a Sample Time, Ts parameter.

On the Parameters tab, if you select Back-emf, the block implements this equation to calculate the permanent flux linkage constant.

λpm=13Ke1000P602π

Motor Construction

This figure shows the motor construction with a single pole pair on the motor.

The motor magnetic field due to the permanent magnets creates a sinusoidal rate of change of flux with motor angle.

For the axes convention, the a-phase and permanent magnet fluxes are aligned when motor angle θr is zero.

Three-Phase Sinusoidal Model Electrical System

The block implements these equations, expressed in the motor flux reference frame (dq frame). All quantities in the motor reference frame are referred to the stator.

ωe=Pωmddtid=1LdvdRLdid+LqLdPωmiq

ddtiq=1LqvqRLqiqLdLqPωmidλpmPωmLq

Te=1.5P[λpmiq+(LdLq)idiq]

The Lq and Ld inductances represent the relation between the phase inductance and the motor position due to the saliency of the motor.

The equations use these variables.

Lq, Ld

q- and d-axis inductances

R

Resistance of the stator windings

iq, id

q- and d-axis currents

vq, vd

q- and d-axis voltages

ωm

Angular mechanical velocity of the motor

ωe

Angular electrical velocity of the motor

λpm

Permanent flux linkage constant

Ke

Back electromotive force (EMF)

P

Number of pole pairs

Te

Electromagnetic torque

Θe

Electrical angle

Mechanical System

The motor angular velocity is given by:

ddtωm=1J(TeTfFωmTm)dθmdt=ωm

The equations use these variables.

J

Combined inertia of motor and load

F

Combined viscous friction of motor and load

θm

Motor mechanical angular position

Tm

Motor shaft torque

Te

Electromagnetic torque

Tf

Motor shaft static friction torque

ωm

Angular mechanical velocity of the motor

Power Accounting

For the power accounting, the block implements these equations.

Bus Signal DescriptionVariableEquations

PwrInfo

PwrTrnsfrd — Power transferred between blocks

  • Positive signals indicate flow into block

  • Negative signals indicate flow out of block

PwrMtr

Mechanical power

Pmot

Pmot= ωmTe
PwrBus

Electrical power

Pbus

Pbus= vania+ vbnib+vcnic

PwrNotTrnsfrd — Power crossing the block boundary, but not transferred

  • Positive signals indicate an input

  • Negative signals indicate a loss

PwrElecLoss

Resistive power loss

Pelec

Pelec= 32(Rsisd2+Rsisq2)
PwrMechLoss

Mechanical power loss

Pmech

When Port Configuration is set to Torque:

Pmech= (ωm2F+ |ωm|Tf)

When Port Configuration is set to Speed:

Pmech= 0 

PwrStored — Stored energy rate of change

  • Positive signals indicate an increase

  • Negative signals indicate a decrease

PwrMtrStored

Stored motor power

Pstr

Pstr= Pbus+ Pmot+ Pelec + Pmech

The equations use these variables.

Rs

Stator resistance

ia, ib, ic

Stator phase a, b, and c current

isq, isd

Stator q- and d-axis currents

van, vbn, vcn

Stator phase a, b, and c voltage

ωm

Angular mechanical velocity of the rotor

F

Combined motor and load viscous damping

Te

Electromagnetic torque

Tf

Combined motor and load friction torque

Ports

Input

expand all

Motor shaft input torque, Tm, in N·m.

Dependencies

To create this port, select Torque for the Port Configuration parameter.

Angular velocity of the motor, ωm, in rad/s.

Dependencies

To create this port, select Speed for the Port Configuration parameter.

Stator terminal voltages, Va, Vb, and Vc, in V.

Dependencies

To create this port, select Speed or Torque for the Port Configuration parameter.

Output

expand all

The bus signal contains these block calculations.

Signal DescriptionVariableUnits

IaStator

Stator phase current A

ia

A

IbStator

Stator phase current B

ib

A

IcStator

Stator phase current C

ic

A

IdSync

Direct axis current

id

A

IqSync

Quadrature axis current

iq

A

VdSync

Direct axis voltage

vd

V

VqSync

Quadrature axis voltage

vq

V

MtrSpd

Angular mechanical velocity of the motor

ωm

rad/s

MtrPos

Motor mechanical angular position

θm

rad

MtrTrq

Electromagnetic torque

Te

N·m

PwrInfo

PwrTrnsfrd

PwrMtr

Mechanical power

Pmot

W
PwrBus

Electrical power

Pbus

W

PwrNotTrnsfrd

PwrElecLoss

Resistive power loss

Pelec

W
PwrMechLoss

Mechanical power loss

Pmech

W

PwrStored

PwrMtrStored

Stored motor power

Pstr

W

Phase a, b, c current, ia, ib, and ic, in A.

Motor torque, Tmtr, in N·m.

Dependencies

To create this port, select Speed for the Mechanical input configuration parameter.

Angular speed of the motor, ωmtr, in rad/s.

Dependencies

To create this port, select Torque for the Mechanical input configuration parameter.

Parameters

expand all

Block Options

This table summarizes the port configurations.

Port ConfigurationCreates Input PortCreates Output Port

Torque

LdTrq

MtrSpd

Speed

Spd

MtrTrq

By default, the block uses a continuous sample time during simulation. If you want to generate code for single-precision targets, considering setting the parameter to Discrete.

Dependencies

Setting Simulation type to Discrete creates the Sample Time, Ts parameter.

Integration sample time for discrete simulation, in s.

Dependencies

Setting Simulation type to Discrete creates the Sample Time, Ts parameter.

Parameters

Motor pole pairs, P.

Stator phase resistance per phase, Rs, in ohm.

Stator d-axis and q-axis inductance, Ld, Lq, in H.

Permanent flux linkage constant, λpm, in Wb.

Back electromotive force, EMF, Ke, in Vpk_LL/krpm. Vpk_LL is the peak voltage line-to-line measurement.

To calculate the permanent flux linkage constant, the block implements this equation.

λpm=13Ke1000P602π

Mechanical properties of the motor:

  • Inertia, J, in kgm^2

  • Viscous damping, F, in N·m/(rad/s)

  • Static friction, Tf, in N·m

Dependencies

To enable this parameter, select the Torque configuration parameter.

Initial Values

Initial q- and d-axis currents, iq, id, in A.

Initial motor angular position, θm0, in rad.

Initial angular velocity of the motor, ωm0, in rad/s.

Dependencies

To enable this parameter, select the Torque configuration parameter.

References

[1] Kundur, P. Power System Stability and Control. New York, NY: McGraw Hill, 1993.

[2] Anderson, P. M. Analysis of Faulted Power Systems. Hoboken, NJ: Wiley-IEEE Press, 1995.

Extended Capabilities