hdl coder synchronism problem

2 views (last 30 days)
Marco
Marco on 30 Apr 2014
Commented: Marco on 2 May 2014
Hi all, I have a problem related to synchronism of the paths of the simulink model shown in the attached figure after the simulink-vhdl conversion. As you can see from figure there is a path without any delay so after vhdl conversion this path is translated in a pure combinatorial logic while the paths with the delay are translated in a process with clock and reset in the sensitivity list. This has 2 main effects: - the overall output is asynchronous so it changes not only during the positive edge of the clock (as I want) - during the reset phase the output doesn't reset since no process with a reset is present in the path without delay. I tried to insert a zero-order hold at the input to synchronise the paths but this trick doesn't work. Any idea about my issue?? Thanks

Accepted Answer

Tim McBrayer
Tim McBrayer on 1 May 2014
Can you register your inputs our outputs (or both)? HDL Coder supports this via its subsystem pipelining capability; this can be implemented without modifying the Simulink diagram or changing the Simulink simulation behavior. You can access the HDL-specific settings by right-clicking on the subsystem and choosing HDL Code>HDL Block Properties.
An alternative solution, of course, is to add any necessary additional delays directly to the Simulink model.
  1 Comment
Marco
Marco on 2 May 2014
Thanks Tim, your suggestion solved my issue.

Sign in to comment.