How to add radiation heat transfer to 3-Zone Pipe (2P) ?
2 views (last 30 days)
Show older comments
Hi, I would like to know if there is a way to add radiative heat transfer to the 3 zone pipe? Problem is, thermal port outputs after convective heat transfer. Radiative transfer needs to be parallel to the convective transfer. I am trying to model a simple condenser with significant radiative heat transfer.
I wonder whether it can work if I input equivalent resistance (convective and radiative) to the External environment heat transfer coefficient?
0 Comments
Answers (1)
Yifeng Tang
on 20 Jul 2022
This may be a workaround:
May the convective transfer coefficient in the 3-zone pipe ridiculously large, so it results in almost no thermal resistance. Then you can add parallel convective and radiative heat transfer to the H port to do what you want.
0 Comments