Fuzzy control problem: input 2 expects a value in range [-50 50], but has a value of 1035.94
Show older comments
I got these warning while running my model
Warning:In 'bismillahfuzzysmc/SMC Controller/Position Controller XY/X Position Controller/Fuzzy Logic
Controller
with Ruleviewer/Fuzzy Logic
Controller', input 2 expects a value in range [-50 50], but has a value of 1035.94.
Warning:In 'bismillahfuzzysmc/SMC Controller/Position Controller XY/X Position Controller/Fuzzy Logic
Controller
with Ruleviewer/Fuzzy Logic
Controller', no rules fired for Output 1. Defuzzified output value set to its mean range value 0.
I already tried to adjust the input 2 but still got those warnings
Here's the block :

Here's the fis file:
[System]
Name='Ux3_'
Type='mamdani'
Version=2.0
NumInputs=2
NumOutputs=1
NumRules=49
AndMethod='min'
OrMethod='max'
ImpMethod='min'
AggMethod='max'
DefuzzMethod='centroid'
[Input1]
Name='x'
Range=[-5.5 5.5]
NumMFs=7
MF1='NH':'trapmf',[-6.875 -5.5 -4.95 -3.575]
MF2='NM':'trimf',[-4.675 -3.575 -2.2]
MF3='NL':'trimf',[-3.575 -2.2 -0.825]
MF4='Z':'trimf',[-0.825 0 0.825]
MF5='PL':'trimf',[0.825 2.2 3.575]
MF6='PM':'trimf',[2.2 3.575 4.95]
MF7='PH':'trapmf',[3.575 4.95 6.325 7.7]
[Input2]
Name='x_derivative'
Range=[-50 50]
NumMFs=7
MF1='NH':'trapmf',[-58.33 -50 -41.67 -33.33]
MF2='NM':'trimf',[-41.67 -33.33 -25]
MF3='NL':'trimf',[-33.33 -20 -8.333]
MF4='Z':'trimf',[-8.333 0 8.333]
MF5='PL':'trimf',[8.333 20 33.33]
MF6='PM':'trimf',[25 33.33 41.67]
MF7='PH':'trapmf',[33.33 41.67 50 58.33]
[Output1]
Name='output1'
Range=[-2e-06 2e-06]
NumMFs=7
MF1='NH':'trapmf',[-2.7e-06 -2.2e-06 -1.557e-06 -1.057e-06]
MF2='NM':'trimf',[-1.557e-06 -1.057e-06 -5.568e-07]
MF3='NL':'trimf',[-1.057e-06 -5.568e-07 -5.68e-08]
MF4='Z':'trimf',[-1.72e-08 0 3.6e-08]
MF5='PL':'trimf',[9e-08 5.9e-07 1.09e-06]
MF6='PM':'trimf',[5.9e-07 1.09e-06 1.59e-06]
MF7='PH':'trapmf',[1.09e-06 1.59e-06 2.088e-06 2.588e-06]
[Rules]
1 1, 7 (1) : 1
2 1, 7 (1) : 1
3 1, 7 (1) : 1
4 1, 7 (1) : 1
5 1, 6 (1) : 1
6 1, 5 (1) : 1
7 1, 4 (1) : 1
1 2, 7 (1) : 1
2 2, 7 (1) : 1
3 2, 7 (1) : 1
4 2, 6 (1) : 1
5 2, 5 (1) : 1
6 2, 4 (1) : 1
7 2, 3 (1) : 1
1 3, 7 (1) : 1
2 3, 7 (1) : 1
3 3, 6 (1) : 1
4 3, 5 (1) : 1
5 3, 4 (1) : 1
6 3, 3 (1) : 1
7 3, 3 (1) : 1
1 4, 7 (1) : 1
2 4, 6 (1) : 1
3 4, 5 (1) : 1
4 4, 4 (1) : 1
5 4, 3 (1) : 1
6 4, 3 (1) : 1
7 4, 2 (1) : 1
1 5, 6 (1) : 1
2 5, 5 (1) : 1
3 5, 4 (1) : 1
4 5, 3 (1) : 1
5 5, 3 (1) : 1
6 5, 2 (1) : 1
7 5, 2 (1) : 1
1 6, 5 (1) : 1
2 6, 4 (1) : 1
3 6, 3 (1) : 1
4 6, 3 (1) : 1
5 6, 2 (1) : 1
6 6, 2 (1) : 1
7 6, 1 (1) : 1
1 7, 4 (1) : 1
2 7, 3 (1) : 1
3 7, 3 (1) : 1
4 7, 2 (1) : 1
5 7, 1 (1) : 1
6 7, 1 (1) : 1
7 7, 1 (1) : 1
Answers (1)
Sam Chak
on 1 Jun 2024
0 votes
Hi Rafi,
Based on your Simulink model, Input 2 refers to the time derivative of the error signal. In the fuzzy system, you have set the Range to [-50 50], but in your Simulink model, you did not limit the output of the derivative block.
For instance, if there is an ideal discontinuous jump in the error signal, the slope of the signal at the instantaneous jump would be infinity. In your case, the slope of the measured error signal is 1035.94. However, this value is outside of the specified range of [-50 50]. Consequently, it triggers the corresponding Warning message.
I would suggest addressing the first Warning message first, before moving on to the second Warning message.
8 Comments
Rafi
on 1 Jun 2024
Sam Chak
on 1 Jun 2024
Thank you for the additional information. Based on your latest update, the 3rd error suggests that your custom fuzzy SMC is unable to stabilize the system. This issue is likely caused by the newly added Saturation block in your Simulink model.
The actual time derivative of the error signal appears to be much higher than the range of [-50, 50] that you have set. However, by forcefully limiting the output to this range, you may have introduced further instability in the system.
Sam Chak
on 2 Jun 2024
From the block diagram above, your Controller equation looks like this:
Controller = m/U₁·{xᵣ" + 10·(2·e + de/dt) + 42.6468·de/dt + [ƒ(e, de/dt) + a₁]·sign(2·e + de/dt)}.
To prevent the sudden discontinuous jump in the error that causes the very high slope (> 1000), insert a low pass filter (50/amp)/(s + 50/amp) at the Desired reference input signal, where amp is the amplitude of the desired signal. The Saturation block is not needed.
The method will limit the amplitude of de/dt in the range [-50, 50]. Please refer to this example:
https://www.mathworks.com/matlabcentral/answers/2118566-fuzzy-control-problem-1-input-2-expects-a-value-in-range-1-5-1-5-but-has-a-value-of-4-36559e-24#answer_1458246
Rafi
on 3 Jun 2024
Rafi
on 3 Jun 2024
Rafi
on 4 Jun 2024
Sam Chak
on 4 Jun 2024
Hi @Rafi
If the designed range of the input time derivative of the error (de/dt) to the Fuzzy Logic block is reduced to [-20, 20] m/s, then the desired position must not exceed this range of [-4, 4] m. The transfer function of the lowpass filter remains
.
. If the designed range of the position error 'e' to the Fuzzy Logic block is increased to [-20, 20] m, then the range of the input time derivative of the error (de/dt) to the Fuzzy Logic block must be increased to [-100, 100] m/s.
If your pitch controller has a similar fuzzy system design as the X controller, then the same approach can be implemented.