MATLAB Answers

Continuous sample time is not supported by discrete derivative

133 views (last 30 days)
Javier Guiterrez
Javier Guiterrez on 10 May 2011
Commented: Firas on 9 Jun 2020
Hello:
I want to know if there exist typical causes for having errors when dealing with discrete derivative block in Simulink. My error is:
"Continuous sample time is not supported by block 'Controller)/Controller/increment/Discrete Derivative/TSamp'"
Although it is a discrete system, it says somthing like a continuous signal is arriving to this block and this is not supported. I have realized before that when there exist huge variations of the input signal in the first time steps, the same o similar error appears.
Thank you in advance

Accepted Answer

Arnaud Miege
Arnaud Miege on 10 May 2011
Without seeing the model, it's difficult to be specific, but it sounds like you are trying feed a discrete block with a continuous signal. Insert a Rate Transition block with the appropriate sample time before the discrete block and that should fix it. You should also read the section of the documentation on Working with sample times.
HTH,
Arnaud