Main Content

Monitor Signals by Using Simulink Real-Time Explorer

This procedure uses the model slrt_ex_osc. You must have already completed this setup:

Open model slrt_ex_osc. Set property Stop time to inf. On the Simulink Editor Real-Time tab, select Run on Target > Stop Time and set the Stop Time to inf.

Connect to the target computer. Toggle the Disconnected indicator to Connected.

Build and download the real-time application to the target computer. Click Run on Target.

Open Simulink® Real-Time™ Explorer. Click Prepare > SLRT Explorer.

To monitor a signal in the real-time application, in Simulink Real-Time Explorer, click Load Application. Select the slrt_ex_osc application from the Applications on target computer list and click Load.

Click the Signals tab.

Select the signals to monitor from the list, and then click Add to signals in instrument Image of add to signals in instrument button. To monitor signals, click Start Streaming. To display the monitored signal values, click View Values.

To start the real-time application, click Start.

To view the signals in the Simulation Data Inspector, click Data Inspector.

To stop execution, click Stop.