Back-emf Constant (V/rpm) of PM DC machine
2 views (last 30 days)
Show older comments
Dear Mathworks Support, The Back-emf constant of permanent magnet DC machine is in V/rpm in the parameters dialog. But it should be V/(rad/s). Am I right? Dan
0 Comments
Answers (1)
Sandip Kumar
on 7 Oct 2014
You indeed are correct, it should be V/rad/s compared to the mentioned V/rpm at the following location: http://www.mathworks.com/help/physmod/sps/powersys/ref/dcmachine.html
I will inform our developers about it.
Thanks, Sandip, MathWorks
0 Comments