How do I enable Simscape Multibody Link Creo-Pro/E Plug-In when my Creo installation is on a server? I cannot modify the protk.dat file.

Accepted Answer

MathWorks Support Team
MathWorks Support Team on 8 Oct 2022
Edited: MathWorks Support Team on 8 Oct 2022
Major concepts are described in the following link, but some more information is included here:
Specific steps are given below:
1. Create a separate '.dat' registry file if one cannot modify the protk.dat file. One can save this separate registry file in a folder that does not get rewritten. Let's say this file is myprotk.dat and is saved at C:/Users/yourusername/Documents/myprotk.dat. This file should contain the following lines:
name Simscape Multibody Link
startup dll
exec_file matlabroot/bin/os/cl_proe2sm.dll
text_dir matlabroot/toolbox/physmod/smlink/cad_systems/proe/text
unicode_encoding false
end
(Replace matlabroot with the absolute path to your MATLAB root folder and os with your operating system architecture.)
2. Since we are using a second '.dat' registry file in addition to the default protk.dat, an additional step is to let Creo know that there is a second '.dat' file to use. In order to do so, one needs to add a line in the config.pro file for Creo. A config.pro file might be under the root or startup directory of the Creo application, which in the case of network server, could be rewritten as with the protk.dat file. However, according to the following article, Creo may look for the config.pro file in multiple directories, and if one exists in each of those directories, Creo has a preference to use the one in the user's Creo Working Directory.
Therefore, one can copy/paste the default config.pro file from the network installation folder to the user's Creo working directory, which typically resides in the "My Document" folder. In this copy, add the following line and save.
toolkit_registry_file C:\Users\yourusername\Documents\myprotk.dat
3. Once the above configuration is completed, start Creo Parametric or Pro/ENGINEER application. In Creo Parametric, search for a Tools menu with a Simscape Multibody Link option. In Pro/ENGINEER Wildfire, search for a Simscape Multibody Link menu. If the option or menu is present, the plug-in is enabled, it is ready to start exporting CAD assemblies.
Note, when editing the .dat and .poj files, make sure that Unicode formatting is disabled. Using the Unicode formatting has been noticed to cause issues.