Simulink Parameter Estimation (CMD) - OutputData only partly available
Show older comments
Good Afternoon,
I want to estimate parameters for a Simulink-Model. It has two phases, charge and discharge. I only have the experimantal data for the discharge-phase to base my parameter-estimation on. Nevertheless, my Simulink-Output is continuous, consisting of both charge and discharge-phase.
What can I do? I think simulink is not able to shrink the output-signal to the relevant part?
Best Regards, Florian
2 Comments
Ryan G
on 21 Jun 2013
Why don't you only run your model from the start-end of the discharge phase?
Arkadiy Turevskiy
on 22 Jun 2013
Another option is to write a custom cost function that only uses simulation results from discharge phase. That would require setting up the estimation problem through code instead of a GUI.
The easier option would be to simulate the charge state, save results using SimState and run discharge phase for parameter estimation by initializing from SimState.
Answers (0)
Categories
Find more on Parameter Estimation in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!