Hydraulic pipeline with resistive, fluid inertia, fluid compressibility, and elevation properties
Low-Pressure Blocks
The Segmented Pipe LP block models hydraulic pipelines with circular cross sections. Hydraulic pipelines, which are inherently distributed parameter elements, are represented with sets of identical, connected in series, lumped parameter segments. It is assumed that the larger the number of segments, the closer the lumped parameter model becomes to its distributed parameter counterpart. The equivalent circuit of a pipeline adopted in the block is shown below, along with the segment configuration.
Pipeline Equivalent Circuit
Segment Configuration
The model contains as many Constant Volume Hydraulic Chamber blocks as there are segments. The chamber lumps fluid volume equal to
where
V | Fluid volume |
d | Pipe diameter |
L | Pipe length |
N | Number of segments |
The Constant Volume Hydraulic Chamber block is
placed between two branches, each consisting of a Resistive
Pipe LP block and a Fluid Inertia block. Every Resistive
Pipe LP block lumps (
-th
portion of the pipe length, while Fluid Inertia block
has L
+L_ad
)/(N
+1)
length
(L
/(N
+1)L_ad
denotes additional pipe length equal
to aggregate equivalent length of pipe local resistances, such as
fitting, elbows, bends, and so on).
The nodes to which Constant Volume Hydraulic Chamber blocks
are connected are assigned names N_1
, N_2
,
…, N_
(n
n
is
the number of segments). Pressures at these nodes are assumed to be
equal to average pressure of the segment. Intermediate nodes between Resistive
Pipe LP and Fluid Inertia blocks are assigned
names nn_0
, nn_1
, nn_2
,
…, nn_
. The Constant
Volume Hydraulic Chamber blocks are named n
ch_1
, ch_2
,
…, ch_
, Resistive
Pipe LP blocks are named n
tb_0
, tb_1
, tb_2
,
…, tb_
, and Fluid
Inertia blocks are named n
fl_in_0
, fl_in_1
, fl_in_2
,
…, fl_in_
.n
The number of segments determines the number of computational nodes associated with the block. A higher number increases model fidelity but decreases simulation speed. Experiment with different numbers to obtain a suitable trade-off between accuracy and speed. Use the following equation as a starting point in estimating a suitable number of segments:
where
N | Number of segments |
L | Pipe length |
c | Speed of sound in the fluid |
ω | Maximum frequency to be observed in the pipe response |
The table below contains an example of simulation of a pipeline where the first four true eigenfrequencies are 89.1 Hz, 267 Hz, 446 Hz, and 624 Hz.
Number of Segments | 1st Mode | 2nd Mode | 3rd Mode | 4th Mode |
---|---|---|---|---|
1 | 112.3 | – | – | – |
2 | 107.2 | 271.8 | – | – |
4 | 97.7 | 284.4 | 432.9 | 689 |
8 | 93.2 | 271.9 | 435.5 | 628 |
As you can see, the error is less than 5% if an eight-segmented version is used.
The difference in elevation between ports A and B is distributed evenly between pipe segments.
The block positive direction is from port A to port B. This means that the flow rate is positive if it flows from A to B, and the pressure loss is determined as .
Flow is assumed to be fully developed along the pipe length.
Internal diameter of the pipe. The default value is 0.01
m.
Pipe geometrical length. The default value is 5
m.
Number of lumped parameter segments in the pipeline model. The
default value is 1
.
This parameter represents total equivalent length of all local
resistances associated with the pipe. You can account for the pressure
loss caused by local resistances, such as bends, fittings, armature,
inlet/outlet losses, and so on, by adding to the pipe geometrical
length an aggregate equivalent length of all the local resistances.
This length is added to the geometrical pipe length only for hydraulic
resistance computation. Both the fluid volume and fluid inertia are
determined based on pipe geometrical length only. The default value
is 1
m.
Roughness height on the pipe internal surface. The parameter
is typically provided in data sheets or manufacturer’s catalogs.
The default value is 1.5e-5
m, which corresponds
to drawn tubing.
Specifies the Reynolds number at which the laminar flow regime
is assumed to start converting into turbulent. Mathematically, this
is the maximum Reynolds number at fully developed laminar flow. The
default value is 2000
.
Specifies the Reynolds number at which the turbulent flow regime
is assumed to be fully developed. Mathematically, this is the minimum
Reynolds number at turbulent flow. The default value is 4000
.
Gauge pressure in the pipe segments at time zero. Enter a scalar
for a single-segment pipeline and a vector for a multi-segment pipeline.
The number of elements in the vector must match the number of segments
in the pipe. The default value is 0
Pa.
The parameter can have one of two values: Rigid
or Flexible
.
If the parameter is set to Rigid
, wall compliance
is not taken into account, which can improve computational efficiency.
The value Flexible
is recommended for hoses and
metal pipes where wall compliance can affect the system behavior.
The default value is Rigid
.
Coefficient that establishes relationship between the pressure
and the internal diameter at steady-state conditions. This coefficient
can be determined analytically for cylindrical metal pipes or experimentally
for hoses. The parameter is used if the Pipe wall type parameter
is set to Flexible
. The default value is 2e-12
m/Pa.
Time constant in the transfer function that relates pipe internal
diameter to pressure variations. By using this parameter, the simulated
elastic or viscoelastic process is approximated with the first-order
lag. The value is determined experimentally or provided by the manufacturer.
The parameter is used if the Pipe wall type parameter
is set to Flexible
. The default value is 0.01
s.
Gas-specific heat ratio for the Constant Volume Hydraulic Chamber
block. The default value is 1.4
.
Vertical position of port A with respect
to a reference plane. The reference plane is assumed to be the same
as that used in the Port B elevation from reference plane parameter.
The default value is 0
m.
Vertical position of port B with respect
to a reference plane. The reference plane is assumed to be the same
as that used in the Port A elevation from reference plane parameter.
The default value is 0
m.
Value of the gravitational acceleration constant (g).
The block uses this parameter to compute the effects of an elevation
gradient between the ports on their pressure differential. The default
value is 9.80655
m/s^2.
When your model is in Restricted editing mode, you cannot modify the following parameter:
Pipe wall type
All other block parameters are available for modification. The actual set of modifiable block parameters depends on the value of the Pipe wall type parameter at the time the model entered Restricted mode.
Parameters determined by the type of working fluid:
Fluid density
Fluid kinematic viscosity
Use the Hydraulic Fluid block or the Custom Hydraulic Fluid block to specify the fluid properties.
The block has the following ports:
A
Hydraulic conserving port associated with the pipe inlet.
B
Hydraulic conserving port associated with the pipe outlet.
[1] White, F.M., Viscous Fluid Flow, McGraw-Hill, 1991