Is it possible to specify a dynamic value for the Integrator block's "Upper Saturation Limit" parameter using an external input?
30 views (last 30 days)
Show older comments
MathWorks Support Team
on 8 Oct 2013
Edited: MathWorks Support Team
on 20 Sep 2022
The Integrator block has an "Upper Saturation Limit" parameter that denotes the upper limit for the integral. I would like to specify a dynamic value for this parameter using an external input to the Integrator block, such that its value is computed by other blocks in my model.
Accepted Answer
MathWorks Support Team
on 20 Sep 2022
Edited: MathWorks Support Team
on 20 Sep 2022
The ability to use an external input to specify a dynamic value for the built-in Integrator block's "Upper Saturation Limit" parameter is not available in Simulink.
To work around this issue, you can use core Simulink blocks to build your own integrator block that allows you to specify dynamic values for its parameters. See the attached Simulink model, named continuous_integrator.mdl, for an example that demonstrates a custom integrator block with external inputs for its "Upper Saturation Limit" and "Lower Saturation Limit" parameters.
0 Comments
More Answers (0)
See Also
Categories
Find more on General Applications in Help Center and File Exchange
Products
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!