time aligning two signal at different sample rates
Show older comments
Most of the techniques I have discovered to time align two signals requires them to be sampled at the same rate. I am aware of the resample() function on matlab but I have a signal sampled at 60 Hz and the other at 200 Hz and I must of course use a rational fraction. Is there a way around this?
1 Comment
dpb
on 13 Aug 2014
Around what, specifically? What do you think you want to resample to?
Answers (1)
Star Strider
on 13 Aug 2014
0 votes
According to the documentation on resample, p and q simply have to be integers, and 60 and 200 meet those requirements. It is probably more reliable to downsample the signal sampled at 200 Hz to 60 Hz sampling.
Categories
Find more on Correlation and Convolution in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!