dbode results in phase shift that is wrong (I believe)
Show older comments
I'm looking at bode plots of linear phase FIR filters and I believe I am getting the wrong phase plot with filter order > 5.
In particular, I'm looking at a moving average filter.
% FIR phase error ?
% LFIR.m
Ts= 1E-3;
n=6;
num= (1/n)*[ones(1,n)];
den= [1 zeros(1,n)];
sys=tf(num,den,Ts);
figure(1); pzmap(sys);
figure(2); dbode(num,den,Ts);
From the pzmap it can be seen that for small positive frequencies on the unit circle the phase contribution should be near zero. However the dbode plot shows the phase at w=0 r/s to be 360 degree. If I use n=5 or less, I do get 0 deg phase at w ~= 0 rad/sec. Is this a problem with dbode?
MATLAB Version: 9.10.0.1739362 (R2021a) Update 5
Here are the pzmap and dbode for n=6:

Accepted Answer
More Answers (0)