xcp on serial Custom board c2000

54 views (last 30 days)
ali
ali on 20 Aug 2023
Answered: ali on 26 Aug 2023
I connected my custom c2000 320f28335 mcu board via sci_a with com port to simulink for xcp debugging, but there is time out error on connection.
Is there any specific hardware configuration?
matlab version 2022b.
the error is :
Could not connect to target application: XCP internal error: timeout expired, in response to XCP CONNECT command
  1 Comment
ali
ali on 23 Aug 2023
Sci-a connected to pc via USB to TTL device, on com port and I configured this port number in hardware configuration in simiulink and also I checked pin number of sci-a

Sign in to comment.

Accepted Answer

ali
ali on 26 Aug 2023
in my case the problem was due to Gnd connection of board and USB to TTL device, I had not connected Gnd,
after I connect it, external mode works correctly