What determines the time axis in spectrogram using normalized frequencies?
Show older comments
I'm attempting to make a spectrogram using normalized frequencies, and the resulting spectrogram looks as expected with the exception of the time axis. Specifically, while the true duration of the data is ~8 minutes, when calculating the spectrogram the time axis ranges to ~21.5 hours!
I've tried manipulating each of the input arguments, and the only thing that seems to affect the time axis is the length of the input data vector - which obviously doesn't make the time axis any more accurate. Any help would be greatly appreciated.
PS: I calculate the normalized frequencies thusly:
FreqsInHz = [0.5:0.1:50]; %The range of frequencies I'm interested in.
SamplingRate = 1000Hz;
normFreqs = (2*pi).*FreqsInHz./SamplingRate; Normalized frequencies in rad/sample.
Answers (1)
Sean de Wolski
on 1 Aug 2016
Time is a function of the sampling frequency, fs.
Compare
spectrogram(rand(1,100000),64,0,64,8000)
spectrogram(rand(1,100000),64,0,64,44100)
For how to use Fs
>> doc spectrogram
1 Comment
Jostein Holmgren
on 1 Aug 2016
Categories
Find more on Digital Filtering in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!