Can I set simbiology repeat assignment rule state to active or inactive using variants?
Show older comments
Using the paradigm similar to that in Dr. Goldspie's insulindemo example, I'm using two rules to set a variable parameter. Let's call the parameter "state_used". In the model, an ODE is used to calculate the species "ODE_state". And I have a function of time calculated to generate "forced_state". One rule sets "state_used" to "ODE_state". The other sets "state_used" to "forced_state". By setting one (and only one) or the other, I can have the model generate the state values, or I can force the state values. For all calculations, the model uses "state_used".
Can I have a variant set a repeat assignment rule to active or inactive?
Or, must I use a MATLAB script to "set" the .Active property to 0 or 1?
An alternate approach would be to have a single assignment rule "ODE_switch" such that
state_used = ODE_switch*ODE_state + (1-ODE_switch)*forced_state
in which case the ODE_switch parameter could be set via variants.
Thanks.