Simulink buffer: How do I fix the error "All sample times must be discrete. No continuous or constant sample times are allowed."

272 views (last 30 days)
I have a discrete scalar input into a simulink buffer and would like the buffer to output a 100x1 vector of the scalar inputs. However, I keep getting this error and I can't figure out why, because the input into the buffer is discrete.

Accepted Answer

Fangjun Jiang
Fangjun Jiang on 1 Nov 2018
Try feeding the Buffer block with a Constant block. Changing the sample time of the Constant block from "inf" to 0.1 (for example) will result in the disappearance of this error message. "inf" means constant sample time.
  4 Comments
dr446
dr446 on 2 Nov 2018
Thanks for your help. The diccrete sample time seems to be correct now. You're right - The block feeding into it was an enabled synchronous subsystem that I think was not definitely discrete, even though it had a discrete output.
Nits
Nits on 24 Jul 2019
Simulink#code generation
Error message: All sample times must be discrete. No continuous or constant sample times are allowed.
I am getting the above mentioned error while building the model in simulink. This error pertains to buffer block which is receiving bitwise data from Dspace via RS232 serial port. Please let me know how to get rid of this error. Thanks in advance.

Sign in to comment.

More Answers (2)

Ahmed Alfadhel
Ahmed Alfadhel on 14 Nov 2018
Edited: Ahmed Alfadhel on 14 Nov 2018
Hello ,
This error is persistent even when I changed the smple time to 0.1 of the input port.
Guys your help plz.

Arif Hussain
Arif Hussain on 29 Jul 2021
I changed sample time of block from 0 to 0.001 and it works perfectly.

Products

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!