Pulse Generator For HDL conversion!
12 views (last 30 days)
Show older comments
Hello;
I want to use simulink HDL coder workflow to generate vhdl code for a block that contains a MATLAB function triggered with a pulse generator (as a clock), but when i try to generate, it says that the pulse generator isn't supported for HDL ! so is there any solution or alternative to generate hdl for a triggered matlab function ??

Also if i try to generate the HDL code for the second sub-system (not including pulse generator but MATLAB function only), it gives me the following error:
The top design unit selected for HDL code generation may not be inside a triggered subsystem.
Is there any solution for this problem please?
3 Comments
Bharath Venkataraman
on 7 May 2021
Edited: Bharath Venkataraman
on 7 May 2021
Yes, the requirements for a triggered subsystem are as you mention.
I do wonder if you need the trigger at all. Can you for example, try to model this without a trigger, and rather with enable/valid signals which run the appropriate logic? Here is an example of how to user valid in/out for model the system.
Accepted Answer
Kiran Kintali
on 15 May 2021
Edited: Kiran Kintali
on 15 May 2021
>> When i try to generate code, HDL Coder says that the pulse generator isn't supported for HDL !

You can build pulse generator logic using basic blocks such as these and generate HDL Code.

0 Comments