Rule
Sub ID a
The icon shape for the Logical Operator block shall be set
to rectangular
.
Custom Parameter
Not Applicable
Example — Correct
Example — Incorrect
Rationale
Sub ID a:
When describing the same function, using a consistent expression improves readability. Since "characteristics” shapes are similar, the risk of misinterpretation is greater than with
rectangular
shapes.
Verification
Model Advisor check: Check icon shape of Logical Operator blocks (Simulink Check)