Error using 4-way valve
Info
This question is closed. Reopen it to edit or answer.
Show older comments
I am having an issue using the 4-way valve Model Parameterization "By pressure-flow characteristic.
I am getting the error.
"Cannot find error message associated with 'sh:orifice_variable:VectorSize'."
My inputs are:
Tabulated Valve Openings [.20 .40 .60 .80 1]
Tabulated Pressure Differentials [2.5 5 10]
Tabulated Flow Rates [0 0 0; 5 10 20; 15 30 60; 40 80 160; 90 180 360;]
I am usinging R2011b
Thank you
Answers (2)
Guy Rouleau
on 3 Feb 2012
0 votes
I am able to reproduce. This is definitely unexpected.
Please contact technical support with your model to report this problem and see if there is a workaround.
Guy Rouleau
on 3 Feb 2012
0 votes
The block should provide a clear error message explaining that the pressure-flow characteristic should have at least 4 values in each dimension.
Consequently, adding one more point to the "Tabulated Pressure Differentials" and one column to "Tabulated Flow Rates" should help.
This question is closed.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!