Simscape: Linear transformer open circuit error
Show older comments
Hello,
I'm trying to model a full-bridge DC-DC converter in simscape. I have the model built using ideal switches for the mosfets with a simple switching scheme. However, when I run the model, even though the simulation time is 0.05s it comes up with an error that at t=8s, the linear transformer is "open-circuited" because a couple switches are off simultaneously. This off-time should happen and is normal for the switching scheme.
I've attached a couple pictures of my diagram and error.


Would this error be because of no anti-parallel diodes with the switches?
Thanks!
1 Comment
Suhan
on 26 May 2017
You can refer to the following article:
Answers (1)
Joel Van Sickel
on 2 Sep 2020
0 votes
Hello Ryan,
yes, you can create circuits that our tool cannot simulate with this topology. If you include things like diodes and snubbers, this can solve the problem.
Regards,
Joel
Categories
Find more on Simscape Electrical in Help Center and File Exchange
Products
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!