Question
Issue with protected model and mask function
Hi there, I've a simulink model with a reference model (calling to a protected model) and a block linked to a library. The libr...
2 years ago | 1 answer | 0
1
answerIssue with native2unicode and windows-1252 encoding
Hi there, Definetely, there must be something I'm missing. I don't understand why numercial numbers 153 and 156 are equally enc...
2 years ago | 0
Issue with native2unicode and windows-1252 encoding
Hi, Sorry for not having completed the post... My question is about why unicode2native returns the same symbol for different n...
2 years ago | 0
Question
Issue with native2unicode and windows-1252 encoding
Hi all, I'm trying to encode some bytes into a character set using the windows-1252 encoding and I've checked that native2unico...
2 years ago | 3 answers | 0
3
answersQuestion
Add same target to protected model
Hi all, I want to create a protected model which support the same target (Embedded Coder), but with different makefiles. I have...
2 years ago | 0 answers | 0
0
answersModel reference function-call output invalid connection
Hello, Here is the exact message I receive. Error due to multiple causes. * Invalid "function-call" connection * Invalid...
10 years ago | 0
Question
Model reference function-call output invalid connection
Hello, I am using a model reference block inside which there is a C MEX S-Function with a function-call output. When I conne...
10 years ago | 2 answers | 1
2
answersQuestion
Data exchange between a C-mex S-function and a function-call subsystem
Hi, I have a Simulink model in which several outputs from a S-Function are connected to a function-call subsystem, also call...
12 years ago | 1 answer | 1