outputSingleScan

Generate single scan on all output channels

Syntax

outputSingleScan(s,data)

Description

example

outputSingleScan(s,data) outputs a single scan of data on one or more analog output channels.

Examples

collapse all

Output a single scan on two analog output voltage channels

Create a session and add two analog output channels.

s = daq.createSession('ni');
addAnalogOutputChannel(s,'cDAQ1Mod2',0:1,'Voltage');

Create an output value and output a single scan for each channel added.

outputSingleScan(s,[1.5 4]);

Output one value on each of two lines on a digital channel

Create a session and add two digital channels from port 0 that measures output only:

s = daq.createSession('ni');
addDigitalChannel(s,'dev1','Port0/Line0:1','OutputOnly')

Output one value each on the two lines:

outputSingleScan(s,[0 1])

Input Arguments

collapse all

Data acquisition session, specified as a session object. Create the session object using daq.createSession. Use the data acquisition session for acquisition and generation operations. Create one session per vendor and use that vendor session to perform all data acquisition operations.

Data to output, represented as a 1-by-n matrix of doubles, where n is the number of output channels in the session.

Introduced in R2010b