Configuration Parameter Considerations
R2026bSolver, diagnostics, and optimization settings
Apply high-integrity guidelines for solver, diagnostics, and optimization settings.
Modeling Guidelines
| hisl_0040: Configuration Parameters > Solver > Simulation time | Set simulation start and stop time parameters for production code generation |
| hisl_0041: Configuration Parameters > Solver > Solver options | Configure fixed-step discrete solver for production code generation |
| hisl_0042: Configuration Parameters > Solver > Tasking and sample time options | Configure explicit rate transitions for multitasking models with preemptive operating systems |
| hisl_0045: Configuration Parameters > Math and Data Types > Implement logic signals as Boolean data (vs. double) | Enable Boolean type checking to support unambiguous logical operator behavior |
| hisl_0048: Configuration Parameters > Math and Data Types > Application lifespan (days) | Set application lifespan to infinity for systems that run continuously |
| hisl_0013: Usage of data store memory | Set data store memory diagnostics to error to identify communication issues |
| hisl_0036: Configuration Parameters > Diagnostics > Saving | Set saving configuration parameters to error to prevent unexpected results |
| hisl_0043: Configuration Parameters > Diagnostics > Solver | Set solver diagnostic parameters to detect configuration issues that could impact code generation |
| hisl_0044: Configuration Parameters > Diagnostics > Sample Time | Set sample time diagnostic parameters to error to support robust code generation |
| hisl_0301: Configuration Parameters > Diagnostics > Compatibility | Set S-function upgrades diagnostic to error to improve design robustness |
| hisl_0302: Configuration Parameters > Diagnostics > Data Validity > Parameters | Set data validity parameter diagnostics to error to improve design robustness |
| hisl_0303: Configuration Parameters > Diagnostics > Data Validity > Merge blocks | Set Merge block driving blocks diagnostic to error to improve design robustness |
| hisl_0304: Configuration Parameters > Diagnostics > Data Validity > Model initialization | Set underspecified initialization detection to simplified to improve design robustness |
| hisl_0305: Configuration Parameters > Diagnostics > Data Validity > Debugging | Set Model Verification block enabling to disable all to improve design robustness |
| hisl_0306: Configuration Parameters > Diagnostics > Connectivity > Signals | Set connectivity signal diagnostics to error to improve design robustness |
| hisl_0307: Configuration Parameters > Diagnostics > Connectivity > Buses | Set connectivity bus diagnostics to error to improve design robustness |
| hisl_0308: Configuration Parameters > Diagnostics > Connectivity > Function calls | Set context-dependent inputs diagnostic to error to improve design robustness |
| hisl_0309: Configuration Parameters > Diagnostics > Type Conversion | Set type conversion diagnostics to detect unsafe conversions and improve design robustness |
| hisl_0310: Configuration Parameters > Diagnostics > Model Referencing | Set model referencing diagnostics to error to improve design robustness |
| hisl_0311: Configuration Parameters > Diagnostics > Stateflow | Set Stateflow diagnostics to error to improve design robustness and promote clear modeling style |
| hisl_0314: Configuration Parameters > Diagnostics > Data Validity > Signals | Set data validity signal diagnostics to error to improve design robustness |
| hisl_0071: Configuration Parameters > Hardware Implementation > Inconsistent hardware implementation settings | Ensure consistent hardware implementation settings between production and test hardware |
| hisl_0037: Configuration Parameters > Model Referencing | Configure model referencing parameters for consistent code generation |
MATLAB Command
You clicked a link that corresponds to this MATLAB command:
Run the command by entering it in the MATLAB Command Window. Web browsers do not support MATLAB commands.
Select a Web Site
Choose a web site to get translated content where available and see local events and offers. Based on your location, we recommend that you select: .
You can also select a web site from the following list
How to Get Best Site Performance
Select the China site (in Chinese or English) for best site performance. Other MathWorks country sites are not optimized for visits from your location.
Americas
- América Latina (Español)
- Canada (English)
- United States (English)
Europe
- Belgium (English)
- Denmark (English)
- Deutschland (Deutsch)
- España (Español)
- Finland (English)
- France (Français)
- Ireland (English)
- Italia (Italiano)
- Luxembourg (English)
- Netherlands (English)
- Norway (English)
- Österreich (Deutsch)
- Portugal (English)
- Sweden (English)
- Switzerland
- United Kingdom (English)